revised 9/7/2016 www.phihong.com 36 w medical grade adapter with interchangeable plugs * *plugs sold separately features ? meets doe level vi and coc v tier 2 ? meets type bf requirements ? field changeabl e ac plugs ? lps compliant ? iec60601 - 1:2005+a:2012 2xmo p p approved ? iec60601 - 1 - 2 ed4 2014 compliant ? ovp, ocp, scp, otp, brown - in and brown - out protections applications ? ventilator s ? workstations ? monitoring machines ? ultrasound machine safety approvals ? ul 60601 - 1 ? ce ? rcm ? iec 60601 - 1 mechanical characteristics ? length: 106.5mm (4.19in) ? height: 38.5 mm (1.52 in ) ? width: 51.5mm (2.03in) ? weight: 220g ( 7.76oz) output specifications (1) test by 20mhz bandwith mode hi resolution with 10uf and 0.1uf capacitor phihong is no t responsible for any error, and reserves the right to make changes without notice. please visit our website at www.phihong.c om for the most up - to - date specifications and contact information. model dc output voltage load ripple (1) p - p (max.) regulation line & lo ad efficiency level case color min. max. pma36r - 120phw 12v 0a 3a 150mv 5% white
pma36 r - 120 ph w characteristics www.phihong.com input: ac input voltage rating 115 to 23 0v ac ac input voltage range 90 to 264v ac ac input frequency 47 to 63hz input current 1.2 a max at 100vac leakage current <100ua at 264vac/50hz inrush current 80 a maximum at 240v ac output: efficiency doe level vi and coc v5 t ier 2 environmental: temperature operation + 10?c to + 40c non - operation - 20?c to +80c relative humidity 90% rh max e missions iec 60601 - 1 - 2:2014 fcc part 18 class b en55011 class b as/nzs cispr11 class b immunity esd: en 61000 - 4 - 2 rs : en6 1000- 4 - 3 eft/burst : en61000 - 4 - 4 surge: en 61000 - 4 - 5 cs : en61000 - 4 - 6 power freque ncy magnetic field : en61000- 4 - 8 voltage dips : en61000 - 4 - 11 o ver - voltage protection 17v auto recover short - circuit protection the power supply shall be protected when operating any output in overload condition, or when operating any output in a short. the power supply shall be self - recovering when the fault condition is removed circuit condition. over - current protection the power supply will be pr otec ted when output power at 4.35a(min ) of all rated dc output . auto - recover over - temperature protection l atch off mode dielectric withstand (hi - pot) test pri. to sec. >4 000vac 10ma for 1 minute dc output connector dc plug type 5.5 x 2.1 x 10mm (fork & groo ve) dc plug pin assignment: inner (+v), outer gnd( - ) medical ac input clips (sold separately) part no: rpa - mab1 w description: us ? white rpb - ma b1 w brazil ? white rpe - mab1 w euro ? white rph - mab1 w korea ? white rpk - mab1 w uk ? white rpn - mab1 w argentina ? white rps - mab1 w au ? white
dimension diagram unit: mm (inch)
|